WINDOWS
More than meets the eye
Technologies
Window Systems
|
|
|
|
||
| ICONIC W77 AI² CE | ICONIC W77 AI² ML | ICONIC W77BS AI² CE | ICONIC W77BS AI² ML | ||
DESIGN |
- | - | - | - | |
| System Depth | mm | 77 | 77 | 77 | 77 |
| Min Face Height Frame-Sash | mm | 89 | 89 | 66 | 66 |
| Min Face Height Threshold-Sash | mm | 79 | 56 | 56 | |
| Min Face Width Middle Mullion | mm | 154 | 154 | 107 | 78 |
| Design |
Minimal Design Linear Design |
Minimal Design Linear Design |
Minimal Design Linear Design |
Minimal Design Linear Design |
|
PROPERTIES |
- | - | - | - | |
| Max Sash Height | mm | 2.800 | 2.800 | 2.500 | 2.500 |
| Max Sash Width | mm | 1.400 | 1.400 | 1.400 | 1.400 |
| Max Sash Weight | kg | 180 | 180 | 130 | 130 |
| Max Glass Thickness | mm | 70 | 70 | 46 or 32 | 46 or 32 |
| Mechanism Type |
Multilock groove mechanism [ML] |
Multilock groove mechanism [ML] |
Multilock groove mechanism [ML] |
Multilock groove mechanism [ML] |
|
| Surface Finishings | All | All | All | All | |
PERFORMANCE |
- | - | - | - | |
| Uf Value (≥) | W/m²K | 0.74 | 0.74 | 1.0 | 1.0 |
| Air Permeability | Class 4 | Class 4 | Class 4 | Class 4 | |
| Watertightness | E1200 | E1200 | Ε1050 | Ε1050 | |
| Resistance to Wind Load | kN/m² | C5/B5 | C5/B5 | C5/B5 | C5/B5 |
| Sound Reduction | 50 | 50 | |||
| Operating Forces |
| ENERGY | |||||||||||
| Uf value ( ≥) EN ISO 10077-2 |
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen. | ||||||||||
| Air Permeability* EN 1026; EN 12207 |
1 (150 Pa) |
2 (300 Pa) |
3 (450 Pa) |
4 (600 Pa) |
|||||||
| Water Tightness** EN 1027;EN 12208 |
3A (100 Pa) |
4A (150 Pa) |
5A (200 Pa) |
6A (250 Pa) |
7A (300 Pa) |
8A (450 Pa) |
9A (600 Pa) |
E750 (750 Pa) |
E1050 (1050 Pa) |
E1200 (1200 Pa) |
|
| Wind Load Resistance*** EN 12211; EN 12210 |
1 (400 Pa) |
2 (800 Pa) |
3 (1200 Pa) |
4 (1600 Pa) |
5 (2000 Pa) |
E (>2000Pa) |
|||||
| Wind Load Resistance, frame deflection*** EN 12211; EN 12210 |
Α (<l/150) |
B (<l/200) |
C (<l/300) |
||||||||
| This table shows classes and values of performances, which can be achieved for specific configurations and opening types. | |
| * | The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure. |
| ** | The Water tightness in a window is its capacity to avoid water penetration. |
| *** | The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance. |
|
||
| ICONIC W77ST AI² | ||
DESIGN |
- | |
| System Depth | mm | 77 |
| Min Face Height Frame-Sash | mm | 68 |
| Min Face Height Threshold-Sash | mm | |
| Min Face Width Middle Mullion | mm | 89 |
| Design |
Minimal Design Industrial Design |
|
PROPERTIES |
- | |
| Max Sash Height | mm | 2.400 |
| Max Sash Width | mm | 1.200 |
| Max Sash Weight | kg | 150 |
| Max Glass Thickness | mm | 56 |
| Mechanism Type |
European groove mechanism [CE] |
|
| Surface Finishings | All |
|
|
|
||
| ESSENCE W67 HI² CE | ESSENCE W67BS HI² CE | ESSENCE W67BS HI² ML | ||
DESIGN |
- | - | - | |
| System Depth | mm | 67 | 67 | 67 |
| Min Face Height Frame-Sash | mm | 89 | 66 | 66 |
| Min Face Height Threshold-Sash | mm | 56 | ||
| Min Face Width Middle Mullion | mm | 154 | 107 | 78 |
| Design | Linear Design |
Minimal Design Linear Design |
Minimal Design Linear Design |
|
PROPERTIES |
- | - | - | |
| Max Sash Height | mm | 2.800 | 2.500 | 2.500 |
| Max Sash Width | mm | 1.400 | 1.400 | 1.400 |
| Max Sash Weight | kg | 180 | 130 | 130 |
| Max Glass Thickness | mm | 60 | 46 or 41 or 28 | 46 or 41 or 28 |
| Mechanism Type |
European groove mechanism [CE] |
European groove mechanism [CE] |
Multilock groove mechanism [ML] |
|
| Surface Finishings | All | All | All | |
PERFORMANCE |
- | - | - | |
| Uf Value (≥) | W/m²K | 1.1 | 1.2 | 1.2 |
| Air Permeability | Class 4 | Class 4 | Class 4 | |
| Watertightness | E1350 | E1050 | E1050 | |
| Resistance to Wind Load | kN/m² | C5/B5 | C5/B5 | C5/B5 |
| Sound Reduction | 44 | 38 | 38 | |
| Operating Forces | Class 1 |
| ENERGY | |||||||||||
| Uf value ( ≥) EN ISO 10077-2 |
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen. | ||||||||||
| Air Permeability* EN 1026; EN 12207 |
1 (150 Pa) |
2 (300 Pa) |
3 (600 Pa) |
4 (600 Pa) |
|||||||
| Water Tightness** EN 1027;EN 12208 |
3A (100 Pa) |
4A (150 Pa) |
5A (200 Pa) |
6A (250 Pa) |
7A (300 Pa) |
8A (450 Pa) |
9A (600 Pa) |
E750 (750 Pa) |
E1050 (1050 Pa) |
E1200 (1200 Pa) |
|
| Wind Load Resistance*** EN 12211; EN 12210 |
1 (400 Pa) |
2 (800 Pa) |
3 (1200 Pa) |
4 (1600 Pa) |
5 (2000 Pa) |
E (>2000Pa) |
|||||
| Wind Load Resistance, to Frame Deflection*** EN 12211; EN 12210 |
Α (<l/150) |
B (<l/200) |
C (<l/300) |
||||||||
| This table shows classes and values of performances, which can be achieved for specific configurations and opening types. | |
| * | The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure. |
| ** | The Water tightness in a window is its capacity to avoid water penetration. |
| *** | The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance. |
|
|
||
| ESSENCE W67ST HI² CE | ESSENCE W67ST HI² ML | ||
DESIGN |
- | - | |
| System Depth | mm | 67 | 67 |
| Min Face Height Frame-Sash | mm | 75.2 | 75 |
| Min Face Height Threshold-Sash | mm | ||
| Min Face Width Middle Mullion | mm | 112.7 | 113 |
| Design | ROUNDED Design [RD] | LINEAR Design [LD] | |
PROPERTIES |
- | - | |
| Max Sash Height | mm | 2.300 | 2.400 |
| Max Sash Width | mm | 800 | 1.200 |
| Max Sash Weight | kg | 80 | 150 |
| Max Glass Thickness | mm | 46 | 46 |
| Mechanism Type |
European groove mechanism [CE] |
Multilock groove mechanism [ML] |
|
| Surface Finishings | All | All |
|
|
|
|
|
||
| ELVIAL W59 SI² CE | ELVIAL W59 SI² CE_RD | ELVIAL W59 SI² ML | ELVIAL W59 SI² ML_RD | ELVIAL W60BS SI² | ||
DESIGN |
- | - | - | - | - | |
| System Depth | mm | 59 | 69 | 59 | 69 | 60 |
| Min Face Height Frame-Sash | mm | 94 | 94 | 94 | 94 | 69 |
| Min Face Height Threshold-Sash | mm | 107 | 103 | 107 | 103 | |
| Min Face Width Middle Mullion | mm | 156 | 156 | 156 | 156 | 93 |
| Design | Linear Design [LD] | Rounded Design [RD] | LINEAR Design [LD] | Rounded Design [RD] |
Minimal Design Linear Design |
|
PROPERTIES |
- | - | - | - | - | |
| Max Sash Height | mm | 2.300 | 2.300 | 2.300 | 2.300 | 2.500 |
| Max Sash Width | mm | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 |
| Max Sash Weight | kg | 130 | 130 | 130 | 130 | 100 |
| Max Glass Thickness | mm | 46 | 36 | 46 | 36 | 24 |
| Mechanism Type |
European groove mechanism [CE] |
European groove mechanism [CE] |
Multilock groove mechanism [ML] |
Multilock groove mechanism [ML] |
Multilock groove mechanism [ML] | |
| Surface Finishings | All | All | All | All | All | |
PERFORMANCE |
- | - | - | - | - | |
| Uf Value (≥) | W/m²K | 1.8 | 2.5 | 1.8 | 2.5 | 2.5 |
| Air Permeability | Class 4 | Class 4 | Class 4 | Class 4 | Class 4 | |
| Watertightness | E1650 | E1650 | E1650 | E1650 | E1050 | |
| Resistance to Wind Load | kN/m² | C5/B5 | C5/B5 | C5/B5 | C5/B5 | C5/B5 |
| Sound Reduction | 40 | 40 | ||||
| Operating Forces |
| ENERGY | |||||||||||
| Uf value ( ≥) EN ISO 10077-2 |
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen. | ||||||||||
| Air Permeability* EN 1026; EN 12207 |
1 (150 Pa) |
2 (300 Pa) |
3 (600 Pa) |
4 (600 Pa) |
|||||||
| Water Tightness** EN 1027;EN 12208 |
7A (300 Pa) |
8A (450 Pa) |
9A (600 Pa) |
E750 (750 Pa) |
E900 (900 Pa) |
E1050 (1050 Pa) |
E1200 (1200 Pa) |
E1350 (1350 Pa) |
E1500 (1500 Pa) |
E1650 (1650 Pa) |
|
| Wind Load Resistance*** EN 12211; EN 12210 |
1 (400 Pa) |
2 (800 Pa) |
3 (1200 Pa) |
4 (1600 Pa) |
5 (2000 Pa) |
E (>2000Pa) |
|||||
| Wind Load Resistance, to Frame Deflection*** EN 12211; EN 12210 |
Α (<l/150) |
B (<l/200) |
C (<l/300) |
||||||||
| This table shows classes and values of performances, which can be achieved for specific configurations and opening types. | |
| * | The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure. |
| ** | The Water tightness in a window is its capacity to avoid water penetration. |
| *** | The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance. |
|
|
||
| ELVIAL W89 PHI² CE | ELVIAL W89 PHI² ML | ||
DESIGN |
- | - | |
| System Depth | mm | 89 | 89 |
| Min Face Height Frame-Sash | mm | 89 | 89 |
| Min Face Height Threshold-Sash | mm | ||
| Min Face Width Middle Mullion | mm | 154 | 154 |
| Design | LINEAR Design [LD] | LINEAR Design [LD] | |
PROPERTIES |
- | - | |
| Max Sash Height | mm | 2.800 | 2.800 |
| Max Sash Width | mm | 1.600 | 1600 |
| Max Sash Weight | kg | 200 | 200 |
| Max Glass Thickness | mm | 83 | 83 |
| Mechanism Type |
European groove mechanism [CE] |
Multilock groove mechanism [ML] |
|
| Surface Finishings | All | All | |
PERFORMANCE |
- | - | |
| Uf Value (≥) | W/m²K | 0.62 | 0.62 |
| Air Permeability | Class 4 | Class 4 | |
| Watertightness | E1050 | E1050 | |
| Resistance to Wind Load | kN/m² | C4/B4 | C4/B4 |
| Sound Reduction | |||
| Operating Forces |
|
||
| ELVIAL W92 HI² AW | ||
DESIGN |
- | |
| System Depth | mm | 92 |
| Min Face Height Frame-Sash | mm | 109 |
| Min Face Height Threshold-Sash | mm | |
| Min Face Width Middle Mullion | mm | 164 |
| Design | LINEAR Design [LD] | |
PROPERTIES |
- | |
| Max Sash Height | mm | 2.400 |
| Max Sash Width | mm | 1.600 |
| Max Sash Weight | kg | 130 |
| Max Glass Thickness | mm | 48 |
| Mechanism Type |
Alu-Wood mechanism [AW] |
|
| Surface Finishings | All | |
PERFORMANCE |
- | |
| Uf Value (≥) | W/m²K | 1.1 |
| Air Permeability | Class 4 | |
| Watertightness | 7A | |
| Resistance to Wind Load | kN/m² | C4/B4 |
| Sound Reduction | ||
| Operating Forces |
| ENERGY | |||||||||||
| Uf value ( ≥) EN ISO 10077-2 |
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen. | ||||||||||
| Air Permeability* EN 1026; EN 12207 |
1 (150 Pa) |
2 (300 Pa) |
3 (600 Pa) |
4 (600 Pa) |
|||||||
| Water Tightness** EN 1027;EN 12208 |
4A (150 Pa) |
5A (200 Pa) |
6A (250 Pa) |
7A (300 Pa) |
8A (450 Pa) |
9A (600 Pa) |
E750 (750 Pa) |
E900 (900 Pa) |
E1050 (1050 Pa) |
E1200 (1200 Pa) |
|
| Wind Load Resistance*** EN 12211; EN 12210 |
1 (400 Pa) |
2 (800 Pa) |
3 (1200 Pa) |
4 (1600 Pa) |
5 (2000 Pa) |
E (>2000Pa) |
|||||
| Wind Load Resistance, to Frame Deflection*** EN 12211; EN 12210 |
Α (<l/150) |
B (<l/200) |
C (<l/300) |
||||||||
| This table shows classes and values of performances, which can be achieved for specific configurations and opening types. | |
| * | The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure. |
| ** | The Water tightness in a window is its capacity to avoid water penetration. |
| *** | The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance. |
ELVIAL aluminium systems are the framework that highlights your space; they give form, character, and long-lasting value to every detail.
Aluminium systems combine technological excellence, aesthetics, and durability over time, offering thermal comfort and absolute security.
Enjoy outstanding thermal insulation and sound reduction, watertight performance in all weather conditions, advanced security mechanisms, and ease of use.
With a wide range of designs, colors, and finishes, ELVIAL aluminium systems integrate harmoniously into every architectural style, from industrial to minimal.
ELVIAL aluminium opening systems offer flexibility and aesthetics for every need and style from small openings to large surfaces.
Ideal for high-end residences, commercial spaces, and renovation projects, ELVIAL aluminium systems combine thermal insulation, security, and timeless design.
They support sustainable and bioclimatic design projects, while their slim lines and minimal aesthetics provide freedom in every architectural composition.
Explore the ELVIAL aluminium casement systems collection and discover a space where technology meets the view.